Hello all,
I got the following error during the alignment of movies.
error, cannot open file (/dev/null)
Though the job finished aligning all the movies, but not able to terminate the job.
Is it because of insufficient memory?
When I tried to bin during importing, it does not have any error.
Thanks
File:
the /dev/null is an error you can hopefully ignore. IF it runs on bin samples, it may be a memory problem.
How many processes are you using? You may need to use less.
Thanks,
Tim
It is related to summed images to display in GUI. No, error with summed images for display checked.
Are aligned images are dose weighted as I provided the dose per frame during the import of movies?
Thanks
They are by default, you can turn this off an expert option.
Tim
Thanks
Is there a way to restart the same job that was stopped due to rebooting of the system?
No, results are not stored until a job completes. so if it dies partway through it has to be run again. Once finished, the results will be saved.
Tim